Output Standard Rated Net COP in OpenStudio different from Input Rated COP in EnergyPlus report - Unmet Hours

Por um escritor misterioso
Last updated 29 julho 2024
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
I'm setting efficiency (COP) of some DX Cooling Coil Single Speed in the AirLoop Packaged Rooftop Heat Pump equipment for compliance Baseline of ASHRAE 90.1. I'm setting the Rated COP field to the desired efficiency according to the standard. However, when opening the EnergyPlus results, in the report Equipment Summary, the Standard Rated Net COP is different, lower than what I had set the input. This only happens in the DX Cooling Coils, but does not happen in DX Heating Coils, where the outputs are the same as inputs. Could someone help me understand why this difference and how to properly adjust the inputs according to the standard.
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
Applied Sciences, Free Full-Text
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
Output Standard Rated Net COP in OpenStudio different from Input Rated COP in EnergyPlus report - Unmet Hours
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
OpenStudio-HPXML/docs/source/workflow_inputs.rst at master · NREL/OpenStudio-HPXML · GitHub
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
Group – Water Heaters: Input Output Reference — EnergyPlus 8.0
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
Refrigeration Equipment: Engineering Reference — EnergyPlus 8.0
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
Air thickness in OpenStudio? - Unmet Hours
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
Group – Plant Equipment: Input Output Reference — EnergyPlus 8.0
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
What is the output that defines the cooling/heating loads that appear on Openstudio results? - Unmet Hours
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
2018 Book BuildingEnergyModelingWithOpen PDF, PDF, Proprietary Software
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
Energy and cost assessment of packaged ice energy storage implementations using OpenStudio Measures - ScienceDirect
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
Energy and cost assessment of packaged ice energy storage implementations using OpenStudio Measures - ScienceDirect
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
The Radiant Whole Life Carbon Study by Introba - Issuu
Output Standard Rated Net COP in OpenStudio different from Input Rated  COP in EnergyPlus report - Unmet Hours
Honeybee Primer, PDF, Window

© 2014-2024 hellastax.gr. All rights reserved.